最新国产午夜精品视频不卡_亚洲欧洲无卡二区视頻_无码丰满少妇2在线观看_人妻人人澡人人添人人爽人人玩

副標題:通過HOBOware軟件設置記錄儀DATA LOGGER的步驟,0,339,2

瀏覽次數: 本頁關鍵詞:HOBO軟件,HOBO記錄儀,軟件設置 類別: 所屬類別: 解決方案 技術文章

通過HOBOware Pro軟件設置 DATA LOGGER記錄儀記錄數據下載的步驟如下:
Step 1: 打開 Hobo軟件. 通過 USB - Serial cable將 Data Logger 與 PC 連接,
 再在“Device”菜單里選擇 “launch”

Step 2: 在以下界面里選擇“OK”
    根據連接到 USB Serial Cable的不同端口, 會顯示 data logger 已經連接

Step 3: 出現Data logger 配置界面顯示, 設置項目如下:
在 “Description” 欄, the data logger as “Compressor” or “Plant” depending on where it is ment  to be used.
不要勾選 “Battery Voltage” 欄
在 “External Sensor and Module”欄 , 取消 “current sensor”

Step 4: 打開“Configure”,顯示設置界面如下:

在 “External Sensor and Module” , “voltage sensor” 欄設置如下:
  a)Channel Name:    Pressure
  b)Excitation Power:    0.03 sec Warm-up time
  c)Measurement Type : Voltage
  d)RAW:        “Units – V:”    “Value 1” – 0;    “Value 2” – 5
  e)SCALED:        “Units – psig:”    “Value 1” – 0;    “Value 2” – 200

d)一旦進入了模塊, 選擇“Configure” 來設置模塊
e)接著顯示  “ Configuration Successful. Would You like to configure the next channel on this sensor?”                            選 “NO”
f)“Logging Interval” – 8 secs
g)“Sampling Intervals” – 8 secs

使用 SHUTTLE 來 啟動 DATA LOGGER
在SHUTTLE 上啟動 DATA LOGGER
1) Start : 按 On/Off 鍵.
2) 顯示 “Find Device”后 ---選“YES”,接著依次如下顯示并設置:
3) “Hobo is Stopped.. DF:12%; Bat:95%” ---選“Next”
4) “Sensors Found:1..  Show Sensors?” ---選“NO”
5) “ Read out HOBO? HOBO is stopped” ---選“YES”
6) 數據讀取后,顯示“Offload Complete. Restart Hobo?” ---選“YES”
7) “ Are you Sure?” --- 按 “YES”
8)  “Change battery?  Stopped, Battery: 95%”  --- 選 “NO”
9) “Sensors Found: 1   Show Sensors?” – 選 “NO”
Data Logger啟動完成, Shuttle 將顯示 “ Hobo Launched” 

使用 SHUTTLE 來從 DATA LOGGER讀取數據包并關閉DATALOGGER
關閉 DATA LOGGER
1) 按 “ On/Off”鍵來啟動 Shuttle,接著依次如下顯示并設置:
2) “Find Device” --- 選 “YES”
3) “Hobo is Logging.. DF:12%; Bat:95%” --- 按 “Next”鍵
4) “Sensors Found:1..  Show Sensors?” --- 選 “NO”
5) “ Read out HOBO? HOBO is Logging” --- 選 “YES”
6)數據讀取后,顯示“Offload Complete…. Restart Hobo?” --- 選 “YES”
7) “ Are you Sure?” --- 選“YES”
8) “Change battery?  Stopped, Battery: 95%”  --- 選 “ESC”
Data Logger關閉后,Shuttle 顯示 “Complete…Remove Devices” –選 “YES”
按 “OFF” 鍵關閉 Shuttle 

從 HOBO SHUTTLE 下載數據到PC
1)用USB cable 將 Shuttle 與 PC 連接好
2) 按 “ On/Off” 啟動Shuttle.
3) 在 Hobo 軟件界面里, “Device” 欄選 “Manage Shuttle” 項
4) 在 “U-Shuttle Management ”窗口, 按 “Sync Shuttle Clock” 鍵來同步
5) 數據從 Shuttle 下載到 PC 并保存  :
    鉤選相應數據對象
    點擊“Offload Checked”
    點擊“choose”選擇保存的文件夾位置
    點擊“Save Checked” 完成下載保存
     點擊“Close”關閉下載窗口或點擊“Launch Shuttle” 清空

更多HOBO技術問題歡迎隨時咨詢我們HOBO中國總代理商廣州駿凱電子科技有限公司